Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

For the perfect operation you have to set up the following options:

  1. Auswahl vom Select Cosmed Omnia als Spirometriesoftwareas CPET Software in the Interface Selection
    Please compare also with the "Types of the Interface"

    notwendige Datenabfrage-Dialoge aktivieren
    Für den Betrieb an Omnia ist es zwingend notwendig das der Patienten ein Gewicht und einen Größe hat.
    Image Removed
    PDF-Grabbing
    Ist notwendig, damit der PDF-Ausdruck von Omnia in unsere CST-Datei vermerkt wird.
    Image Removed

  2. PDF-Ausdruck/Export
    Image Removed
     


  3. Enable necessary Dialogues to ask the Customer for required Data
    For the Operation of Cosmed Omnia the Weight and Height of the Patient is mandatory!Enable
    Image Added

  4. Enable PDF-Grabbing
    The PDF Grabbing import the PDF into the Evaluation which is printed from Cosmed Omnia as Report while the Test.
    Image Added

  5. Configure the PDF Printout and the Standard Printout
    Image Added
     

  6. Configure the LoginUserName and LoginPassword from Cosmed Omnia
    The Login Credentials are mandatory because its a part of the TCP/IP Communication.
    Image Added

  7. Configure the Program Name of Cosmed Omnia
    This Program will be started if you launch a CPET Test in custo diagnostic.Anmeldedaten/Logindaten für Omnia
    Sind notwendig, da die Kommunikation das Anmelden mit einschließt.
    Image Removed
    Programmname vom Omnia
    Das hier eingestellte Programm wird von custo aufgerufen, die Voreinstellung ist meistens passen


Settings in Cosmed Omnia

  1. Install Cosmed Omnia (min. Version 1.4) on the PC

  2. Start Cosmed Omnia the first Time and make it running

  3. Activate the TCP/IP Interface in the File "\%PUBLIC%\Documents\Cosmed\CosmedLab\ACS.XML". The File exists only you had start Cosmed Omnia one times. After that you have to edit the File manually.

    Code Block
    languagexml
    <ExtendedConfiguration Version="1">
      <General>
        <TimeOutMinCheckValue Type="System.Int32" Value="15" />
        <MenuMatrix Type="Tuple" TypeID="System.Int32" ID="2" TypeValue="System.Int32" Value="3" />
      </General>
      <EntityFramework>
        <SessionTimeout Type="System.Int32" Value="60" />
        <MaxRetryCount Type="System.Int32" Value="5" />
        <MaxDelay Type="System.Int32" Value="26" />
      </EntityFramework>
      <Bridge>
        <Debugger Type="System.Boolean" Value="True" />
        <Control Type="Tuple" TypeID="System.String" ID="tcp" TypeValue="System.String" Value="xml" TypeItem2="System.String" Item2="utf-8" TypeItem3="System.String" Item3="5530" TypeItem4="System.String" Item4="OmniaXB" />
        <Legacy Type="Tuple" TypeID="System.String" ID="legacy" TypeValue="System.String" Value="raw" TypeItem2="System.String" Item2="ascii" TypeItem3="System.String" Item3="" TypeItem4="System.String" Item4="" />
      </Bridge>
      <Ergo>
        <ShowDataOnProtocolChart Type="System.Boolean" Value="True" />
      </Ergo>
    </ExtendedConfiguration>

     To activate the Communication via TCP/IP you have to insert this Line inside the Section <Bridge>:

    Code Block
    languagexml
        <Control Type="Tuple" TypeID="System.String" ID="tcp" TypeValue="System.String" Value="xml" TypeItem2="System.String" Item2="utf-8" TypeItem3="System.String" Item3="5530" TypeItem4="System.String" Item4="OmniaXB" />
    

    Please be careful that only one Line of the Type <Control> in the Section <Bridge> exists.

     

  4. COSMED Start Cosmed Omnia starten
    Anmelden als Admin evtl. muß das Passwort jetzt eingegeben werden, bitte merken, denn es muß auch in die Einstellungen von custo diagnostic übernommen werden.
    Über die Datenbank kann immer der Patienten DEMO SUBJECT gewählt werden wenn einen Messung zu machen ist

    Login as an Administrator. You can use these Credential also in the Configuration in custo diagnostic.
    With the Patient "DEMO SUBJECT" every time a Test can be performed.

  5. Configure the Device K5
    Image Added

  6. Start a test once time and select 'PC Software ECG' as HR Source and 'Ergoline900' as the bike. This is only possible after you had selected the Device K5Das Gerät K5 konfigurieren
    Image Removed
    Einmalig eine Messung starten und als HF-Quelle 'PC Software ECG' und Ergometer 'Ergoline900' wählen.Das geht nur, wenn zuvor das Gerät K5 ausgewählt wurde!



 

Anchor
Types of the Interface
Types of the Interface
Types of the Interface

Unter Einstellungen -> System ->Arbeitsplatz
Image Removed
kann die jeweilige Anbindung an Cosmed ausgewählt werden.Hierbei sind zwei unterschiedliche "Betriebsmodi" auswählbar, die Auswahl ist immer aus Sicht von custo diagnostic system zu sehen.

In custo diagnostic → Settiungs → System → Workstation
Image Added
the Type of Interface to Cosmed Omnia can be selected. This is comparable to an Operation Mode. The Selection is described as View from custo diagnostic.

SelectionOperation ModeAuswahlFunktionsweise

COSMED Omnia (slave)

Cosmed Omnia: Zeigt nur an, steuert NICHT do not control the Training Device
custo diagnostic: Ergometersteuerungcontrol the Training Device

COSMED Omnia (master)
ehemals  
COSMED Omnia

Cosmed Omnia: Ergometersteuerung control the Training Device
custo diagnostic: Zeigt nur an, steuert NICHTdo not control the Training Device


Spezielle Einstellungen in custo diagnostic

...