Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

custo diagnostic 5.x based on a Client-Server-Architecture. If you want to use custo diagnostic 5.x (multi Workstation or Stand-alone does not matter) you have to install the custo diagnostic server 5 at first. The custo diagnostic server 5 is an Tomcat based Application Server with Connection to an local or networkbased Database. At this time 'H2 Database' (included in Tomcat) or 'MS-SQL Database' is supported. The H2 Database should be installed on the same Computer as the custo diagnostic server 5. For MS-SQL Database a local installed or installed on another Computer SQL Server can be used (Please rever also to the custo diagnostic 5 Hardware and Software Requirements).

Installation with H2 Database

...

  1. Start the Server Setup Program


  2. Select the Laguage for the Setup


  3. Click 'Next' on the Welcome Page


  4. Choose the Destination Folder for the custo diagnostic server Installation. Do not install the custo diagnostic server on a network drive or UNC path.


  5. Choose the Destination Folder for the custo diagnostic Evaluation RAW Data and Database (if H2 is selected, not for MS-SQL Database). There the cst files and if selected the H2 Database are saved. The data directory can also be filed on a second local disk. In particular situations, the directory for the cst files can be filed separately from the database directory (e.g. on a file share). However, custo med strongly recommends to leave the whole data directory on the local server computer.


  6. Select the Database Type. H2 Database is recommended.
    Please select here also the most suitable Database Collation for the Database based on the to be stored Patient Demographics.


  7. Select the to be used TCP/IP Ports for custo diagnostic server.
    For 'HTTP Port' (Default Communication) and 'Redirect Port / HTTPS' (Encrypted Communication) you can use every Port as you want. Please clarify these Ports with your Network Administrator. These Port have to be registered also in the Firewall or AntiVirus Solutions. The 'AJP Port' and 'SHUTDOWN Port' can be leaved unchanged. If you click on next the Setup will test if the Ports are available or not. If one or more Ports are used by another Program the Setup will inform you.


  8. Select the Name and Position for the Shortcuts in the Windows Start Menu


  9. The Install Procedure is running


  10. The Install Procedure is completed


  11. Click 'Finish' to end the Install Procedure

...