Please refer to your local sales partner for a HL7 specification.
It's available in the support area at custo med website, Healthcare-IT.
Introduction
Allgemeines zur HL7 Schnittstelle ACK,
General Data Used
Drübergehen DTM Format?
""
Key
Not listed fields are ignored
Default configuration - can be confgured in some extent.
Receiving / Sending seen from custo diagnostic perspective
Common Segments
MSH - Segment
...
Sending Application.
Receiving: Expected value can be configured (default empty) in custo diagnostic and works as a filter - meaning messages with deviant content in MSH-3 are ignored.
Sending: Sending Application, e.g. "CUSTO" can be configured in custo diagnostic.
...
Sending Facility
Receiving: Expected value can be configured in custo diagnostic and works as a filter - meaning messages with deviant content in MSH-4 are ignored.
Sending: Sending Application, e.g. "CUSTO" can be configured in custo diagnostic. When a tenant system (german "Mandantensystem") is configured, this field contains the information about the tenant. See "Tenant System" below.
...
Receiving Application
Receiving: Expected value can be configured (default empty) in custo diagnostic and works as a filter - meaning messages with deviant content in MSH-3 are ignored.
Sending: Receiving Application, can be configured (default empty) in custo diagnostic e.g. "HIS".
...
Receiving Facility
Receiving: Expected value can be configured in custo diagnostic and works as a filter - meaning messages with deviant content in MSH-3 are ignored. When a tenant system (german "Mandantensystem") is configured, this field should contain the information about the tenant. See "Tenant System" below.
Sending: Receiving Facility, can be configured (default empty) in custo diagnostic e.g. "HIS".
...
Message Type. By default, custo diagnostic sends Messagetype^Event^Message-Structure, e.g. ORU^R01^ORU_R01.
...
Version ID,
Sending: Custo diagnostic supports Version 2.3, 2.5
##Verhalten bei eingehenden Nachrichten noch prüfen, wenn 2.7 2.9 oder 1.5 o.ä. drin steht##
...
Character Set ##zu prüfen##
Receiving: see Standard
Sending: By Default empty, ##Tatsächlich verwendetes CodeSet? ???? is used to encode message##
PID - Segment
### Hier bitte alles aus default Mapping übernehmen.###
z.B. PID-3, r, Patient-ID, see HL7 Standard. PID-3-1 is used to identify the patient in custo diagnostic. It must be unique in one custo diagnostic installation, otherwise an appropriate tenant system must be used (see tenant system below).
Required sind patienten name/vorname, geburtsdatum, Patienten-nummer, geschlecht?,
...
Administrative Sex. Supported Values are F, M, ?? Other Values are interpeted as ...
PV1 - Segment
...
Visit-ID. The visit id is used to identify the visit in custo diagnostic It must be unique in one custo diagnostic installation, otherwise an appropriate tenant system must be used (see tenant system below).
Patient Data Logic (ADT)
Tenant System
Orders (ORM)
Observation Results (ORU)
...